6XWS(36)+FC 6XWS(36)+IWRC Stainless Steel Wire Rope

Product Specification
Product Details
Diameter (Mm): 8
Approx. Weight (Kg/100m) FC: 23.49
Approx. Weight (Kg/100m) WSC: 26.18
Minimum Breaking Load (KN) 1570n/mm2 FC: 33.16
Minimum Breaking Load (KN) 1570n/mm2 WSC: 35.77
Minimum Breaking Load (KN) 1770n/mm2 FC: 37.38
Minimum Breaking Load (KN) 1770n/mm2 WSC: 40.33
Minimum Breaking Load (KN) 1960n/mm2 FC: 41.40
Minimum Breaking Load (KN) 1960n/mm2 WSC: 44.66
Diameter (Mm): 12
Approx. Weight (Kg/100m) FC: 52.85
Approx. Weight (Kg/100m) WSC: 58.90
Minimum Breaking Load (KN) 1570n/mm2 FC: 74.61
Minimum Breaking Load (KN) 1570n/mm2 WSC: 80.48
Minimum Breaking Load (KN) 1770n/mm2 FC: 84.11
Minimum Breaking Load (KN) 1770n/mm2 WSC: 90.74
Minimum Breaking Load (KN) 1960n/mm2 FC: 93.14
Minimum Breaking Load (KN) 1960n/mm2 WSC: 100.48
Diameter (Mm): 10
Approx. Weight (Kg/100m) FC: 36.70
Approx. Weight (Kg/100m) WSC: 40.90
Minimum Breaking Load (KN) 1570n/mm2 FC: 51.81
Minimum Breaking Load (KN) 1570n/mm2 WSC: 55.89
Minimum Breaking Load (KN) 1770n/mm2 FC: 58.41
Minimum Breaking Load (KN) 1770n/mm2 WSC: 63.01
Minimum Breaking Load (KN) 1960n/mm2 FC: 64.68
Minimum Breaking Load (KN) 1960n/mm2 WSC: 69.78
Diameter (Mm): 14
Approx. Weight (Kg/100m) FC: 71.93
Approx. Weight (Kg/100m) WSC: 80.16
Minimum Breaking Load (KN) 1570n/mm2 FC: 101.55
Minimum Breaking Load (KN) 1570n/mm2 WSC: 109.55
Minimum Breaking Load (KN) 1770n/mm2 FC: 114.48
Minimum Breaking Load (KN) 1770n/mm2 WSC: 123.50
Minimum Breaking Load (KN) 1960n/mm2 FC: 126.77
Minimum Breaking Load (KN) 1960n/mm2 WSC: 136.76
Diameter (Mm): 15
Approx. Weight (Kg/100m) FC: 82.58
Approx. Weight (Kg/100m) WSC: 92.03
Minimum Breaking Load (KN) 1570n/mm2 FC: 116.57
Minimum Breaking Load (KN) 1570n/mm2 WSC: 125.76
Minimum Breaking Load (KN) 1770n/mm2 FC: 131.42
Minimum Breaking Load (KN) 1770n/mm2 WSC: 141.78
Minimum Breaking Load (KN) 1960n/mm2 FC: 145.53
Minimum Breaking Load (KN) 1960n/mm2 WSC: 157.00
Diameter (Mm): 17
Approx. Weight (Kg/100m) FC: 106.06
Approx. Weight (Kg/100m) WSC: 118.20
Minimum Breaking Load (KN) 1570n/mm2 FC: 149.73
Minimum Breaking Load (KN) 1570n/mm2 WSC: 161.53
Minimum Breaking Load (KN) 1770n/mm2 FC: 168.80
Minimum Breaking Load (KN) 1770n/mm2 WSC: 182.10
Minimum Breaking Load (KN) 1960n/mm2 FC: 186.93
Minimum Breaking Load (KN) 1960n/mm2 WSC: 201.65
Diameter (Mm): 19
Approx. Weight (Kg/100m) FC: 132.49
Approx. Weight (Kg/100m) WSC: 147.65
Minimum Breaking Load (KN) 1570n/mm2 FC: 187.03
Minimum Breaking Load (KN) 1570n/mm2 WSC: 201.77
Minimum Breaking Load (KN) 1770n/mm2 FC: 210.86
Minimum Breaking Load (KN) 1770n/mm2 WSC: 227.47
Minimum Breaking Load (KN) 1960n/mm2 FC: 233.49
Minimum Breaking Load (KN) 1960n/mm2 WSC: 251.89
Diameter (Mm): 20
Approx. Weight (Kg/100m) FC: 146.80
Approx. Weight (Kg/100m) WSC: 163.60
Minimum Breaking Load (KN) 1570n/mm2 FC: 207.24
Minimum Breaking Load (KN) 1570n/mm2 WSC: 223.57
Minimum Breaking Load (KN) 1770n/mm2 FC: 233.64
Minimum Breaking Load (KN) 1770n/mm2 WSC: 252.05
Minimum Breaking Load (KN) 1960n/mm2 FC: 258.72
Minimum Breaking Load (KN) 1960n/mm2 WSC: 279.10
Diameter (Mm): 22
Approx. Weight (Kg/100m) FC: 177.63
Approx. Weight (Kg/100m) WSC: 197.96
Minimum Breaking Load (KN) 1570n/mm2 FC: 250.76
Minimum Breaking Load (KN) 1570n/mm2 WSC: 270.52
Minimum Breaking Load (KN) 1770n/mm2 FC: 282.70
Minimum Breaking Load (KN) 1770n/mm2 WSC: 304.98
Minimum Breaking Load (KN) 1960n/mm2 FC: 313.05
Minimum Breaking Load (KN) 1960n/mm2 WSC: 337.72
Diameter (Mm): 24
Approx. Weight (Kg/100m) FC: 211.39
Approx. Weight (Kg/100m) WSC: 235.58
Minimum Breaking Load (KN) 1570n/mm2 FC: 298.43
Minimum Breaking Load (KN) 1570n/mm2 WSC: 321.94
Minimum Breaking Load (KN) 1770n/mm2 FC: 336.44
Minimum Breaking Load (KN) 1770n/mm2 WSC: 362.95
Minimum Breaking Load (KN) 1960n/mm2 FC: 372.56
Minimum Breaking Load (KN) 1960n/mm2 WSC: 401.91
Diameter (Mm): 26
Approx. Weight (Kg/100m) FC: 248.09
Approx. Weight (Kg/100m) WSC: 276.48
Minimum Breaking Load (KN) 1570n/mm2 FC: 350.24
Minimum Breaking Load (KN) 1570n/mm2 WSC: 377.83
Minimum Breaking Load (KN) 1770n/mm2 FC: 394.85
Minimum Breaking Load (KN) 1770n/mm2 WSC: 425.96
Minimum Breaking Load (KN) 1960n/mm2 FC: 437.24
Minimum Breaking Load (KN) 1960n/mm2 WSC: 471.69
Diameter (Mm): 28
Approx. Weight (Kg/100m) FC: 287.73
Approx. Weight (Kg/100m) WSC: 320.66
Minimum Breaking Load (KN) 1570n/mm2 FC: 406.19
Minimum Breaking Load (KN) 1570n/mm2 WSC: 438.19
Minimum Breaking Load (KN) 1770n/mm2 FC: 457.93
Minimum Breaking Load (KN) 1770n/mm2 WSC: 494.01
Minimum Breaking Load (KN) 1960n/mm2 FC: 507.09
Minimum Breaking Load (KN) 1960n/mm2 WSC: 547.04
Diameter (Mm): 32
Approx. Weight (Kg/100m) FC: 375.81
Approx. Weight (Kg/100m) WSC: 418.82
Minimum Breaking Load (KN) 1570n/mm2 FC: 530.53
Minimum Breaking Load (KN) 1570n/mm2 WSC: 572.33
Minimum Breaking Load (KN) 1770n/mm2 FC: 598.12
Minimum Breaking Load (KN) 1770n/mm2 WSC: 645.24
Minimum Breaking Load (KN) 1960n/mm2 FC: 662.32
Minimum Breaking Load (KN) 1960n/mm2 WSC: 714.51
Diameter (Mm): 36
Approx. Weight (Kg/100m) FC: 475.63
Approx. Weight (Kg/100m) WSC: 530.06
Minimum Breaking Load (KN) 1570n/mm2 FC: 671.46
Minimum Breaking Load (KN) 1570n/mm2 WSC: 724.36
Minimum Breaking Load (KN) 1770n/mm2 FC: 756.99
Minimum Breaking Load (KN) 1770n/mm2 WSC: 816.64
Minimum Breaking Load (KN) 1960n/mm2 FC: 838.25
Minimum Breaking Load (KN) 1960n/mm2 WSC: 904.30
Diameter (Mm): 40
Approx. Weight (Kg/100m) FC: 587.20
Approx. Weight (Kg/100m) WSC: 654.40
Minimum Breaking Load (KN) 1570n/mm2 FC: 828.96
Minimum Breaking Load (KN) 1570n/mm2 WSC: 894.27
Minimum Breaking Load (KN) 1770n/mm2 FC: 934.56
Minimum Breaking Load (KN) 1770n/mm2 WSC: 1008.19
Minimum Breaking Load (KN) 1960n/mm2 FC: 1034.88
Minimum Breaking Load (KN) 1960n/mm2 WSC: 1116.42
Product Description

Stainless Steel Wire Rope Technical Specifications

This page provides a technical specification table for Stainless Steel Wire Rope, including diameter, approximate weight, and minimum breaking load for different tensile strengths (1570N/mm2, 1770N/mm2, 1960N/mm2) with different core types (FC, WSC).

Key Benefits:

  • High Tensile Strength Options
  • Variety of Diameters Available
  • Different Core Types (FC, WSC)
  • Detailed Technical Data

Target Applications:

Suitable for various industrial applications requiring durable and high-strength wire rope, such as lifting, rigging, and structural support.

Product Attributes

FOB Unit: KN
Product MOQ: Unspecified, refer to the inquiry form
FOB Price: 0
Packaging & Delivery: Unspecified, refer to the inquiry form

Technical Specifications

Diameter (mm) Approx. Weight (kg/100m) FC Approx. Weight (kg/100m) WSC Minimum Breaking Load (KN) 1570N/mm2 FC
8 23.49 26.18 33.16
12 52.85 58.90 74.61
10 36.70 40.90 51.81
14 71.93 80.16 101.55
15 82.58 92.03 116.57
17 106.06 118.20 149.73
19 132.49 147.65 187.03
20 146.80 163.60 207.24
22 177.63 197.96 250.76
24 211.39 235.58 298.43
26 248.09 276.48 350.24
28 287.73 320.66 406.19
32 375.81 418.82 530.53
36 475.63 530.06 671.46
40 587.20 654.40 828.96
Diameter (mm) Minimum Breaking Load (KN) 1570N/mm2 WSC Minimum Breaking Load (KN) 1770N/mm2 FC Minimum Breaking Load (KN) 1770N/mm2 WSC
8 35.77 37.38 40.33
12 80.48 84.11 90.74
10 55.89 58.41 63.01
14 109.55 114.48 123.50
15 125.76 131.42 141.78
17 161.53 168.80 182.10
19 201.77 210.86 227.47
20 223.57 233.64 252.05
22 270.52 282.70 304.98
24 321.94 336.44 362.95
26 377.83 394.85 425.96
28 438.19 457.93 494.01
32 572.33 598.12 645.24
36 724.36 756.99 816.64
40 894.27 934.56 1008.19
Diameter (mm) Minimum Breaking Load (KN) 1960N/mm2 FC Minimum Breaking Load (KN) 1960N/mm2 WSC
8 41.40 44.66
12 93.14 100.48
10 64.68 69.78
14 126.77 136.76
15 145.53 157.00
17 186.93 201.65
19 233.49 251.89
20 258.72 279.10
22 313.05 337.72
24 372.56 401.91
26 437.24 471.69
28 507.09 547.04
32 662.32 714.51
36 838.25 904.30
40 1034.88 1116.42
Related Products
Contact Our Experts And Get A Free Consultation!

Our mission is to offer "High Quality" & "Good Service" & "Fast Delivery" to help our clients to gain more profits.